Search
EN

Nephrines Urine ELISA

Brand: Diagnostics
Enzyme immunoassay for the quantitative determination of Metanephrine and Normetanephrine in urine
SKU: DEE8600

Register or Log In in order to request a quote

Register Login

Products specifications
TechnologyELISA
Sizes2x96 tests
>Background:Metanephrine and Normetanephrine are the metabolites of the catecholamines Epinephrine and Norepinephrine, respectively. They are metabolized to Vanillylmandelic acid or excreted with the urine. Patients with pheochromocytoma or other tumors derived from neuroendocrine cells show elevated urinary levels of total Metanephrines. As catecholamine secretion from neuroendocrine cells might show high variations, urine samples collected over a period of 24 hours are used to average these fluctuations. Therapeutic consequences should never be based on laboratory results alone, even if these results are assessed in accordance with the quality criteria of the method. Any laboratory result is only a part of the total clinical picture of the patient. Only in cases where the laboratory results are in an acceptable agreement with the overall clinical picture of the patient, it can be used for therapeutic consequences.

Description:
Enzyme Immunoassay for the quantitative determination of Metanephrine and Normetanephrine in urine. During the sample preparation Metanephrine (Metadrenaline) and Normetanephrine (Normetadrenaline) are quantitatively acylated. The subsequent competitive ELISA uses the microtiter plate format. The antigen is bound to the solid phase of the microtiter plate. The acylated standards, controls and samples compete with the solid phase bound analytes for a fixed number of antibody binding sites. After the system is in equilibrium, free antigen and free antigen-antibody complexes are removed by washing. The antibody bound to the solid phase is detected by an anti-rabbit IgG-peroxidase conjugate using TMB as a substrate resulting in a colour reaction. The reaction is monitored at a wavelength of 450 nm. Quantification of unknown samples is achieved by comparing their absorbance with a reference curve prepared with known standard concentrations. Manual processing of the ELISA is recommended. The use of automatic laboratory equipment is the responsibility of the user. This in-vitro diagnostic is for professional use only.

Product features:
The kit contains reagents for 2x96 determinations (1x96 metanephtine; 1x96 normetanephrine);
Microtiter plate consisting of 12x8;
Microtiter plate reader at 450 nm;
Analytical sensitivity: MT: 13 ng/ml; NMT: 23 ng/ml;
IVD.