Ozone-free, high-density UV decontamination PCR chambers with long-life lamps and UV lamps that automatically turn off when the protection panel is opened. UV irradiation disinfects the work area by inactivating DNA/RNA fragments during a 15 to 30 minute exposure. The cameras have low noise and low power consumption.
SKU: BIOUVT-B-AR

Register or Log In in order to request a quote

Register Login

Products specifications
Sizes
Ozone-free, high-density UV decontamination PCR chambers with long-life lamps and UV lamps automatically turn off when the protection panel is opened. UV irradiation disinfects the work area by inactivating DNA/RNA fragments during a 15 to 30-minute exposure. The cameras have low noise and low power consumption.


CAMERA FOR PCR WITH RECIRCULATION
Chamber with a steel structure and working platform. Front and side panels are made of Euroglas, 8 mm thick on the front and 4 mm on the sides. Stainless steel back. Sterile and UV-filtered air recirculation system that guarantees aseptic conditions inside the cabin during work. Folding front closure. Integrated socket and input for power cables.

Specifications:
- Sterilization with two UV germicidal lamps (30W) and white light for lighting;
- Recirculation system of sterilized air, at 25m3/h, and filtered by UV;
- Front and side panels in euroglass, with 96% UV absorption;
- Available accessories (not included) such as: a table to support the chamber, a module with drawers, support shelf inside the chamber, and shelf to support the micropipettes.
- Dimensions of the work surface: 121 x 50 cm;
- Exterior dimensions (WxDxH): 125 x 60 x 59 cm.


CHAMBER FOR PCR WITH RECIRCULATION
Structure and work base in steel, front panel in glass with anti UV treatment. Sterile and UV-filtered air recirculation system that guarantees aseptic conditions inside the cabin during work. Folding front closure. Integrated socket and input for power cables.

Specifications:
- Sterilization with UV germicidal lamp (15W) of long duration and white light for illumination;
- UV light timer from 1 min to 24 hours;
- Recirculation system of sterilized air, at 25m3/h, and filtered by UV;
- Available accessories (not included) such as: table to support the chamber, module with drawers, support shelf inside the chamber and shelf to support the micropipettes.
- Dimensions of the work surface: 64.5 x 49 cm;
- Exterior dimensions (WxDxH): 69 x 54 x 55 cm.


CHAMBER FOR PCR WITH RECIRCULATION
Chamber with a steel structure and working platform. Front and side panels made of Plexiglas, 8 mm thick on the front and 4 mm on the sides. Sterile and UV-filtered air recirculation system that guarantees aseptic conditions inside the cabin during work. Folding front closure and power socket inside.

Specifications:
- Sterilization with UV lamp (15W) of long duration and white light for illumination;
- UV light timer from 1 min to 24 hours;
- Plexiglas front and side panels (99% UV absorption);
- Recirculation system of sterilized air, at 25m3/h, and filtered by UV;
- Available accessories (not included) such as: table to support the chamber, module with drawers, support shelf inside the chamber and shelf to support the micropipettes.
- Dimensions of the work surface: 64.5 x 49 cm;
- Exterior dimensions (WxDxH): 70 x 58 x 55.5 cm.


ULTRAVIOLET CAMERA TO DISINFECT SURFACES
Ultraviolet chamber, increasing the effectiveness of surface disinfection, removing DNA, RNA and microorganisms. The chamber with highly focused UV light used to disinfect tools, containers and other research items, eliminating up to 99% of surface contamination. Multiple lamps and chamber with reflective walls provide true 360° UV exposure with no blind spots.

Specifications:
- UV light with a wavelength of 254 nm;
- UV exposure of 600 mJ/cm2 (20 min cycle);
- UV intensity of + 500µW/cm² (camera center);
- 5-20 min UV timer. (5 min Inc.);
- Heating temperature of 55°C;
- Internal dimensions (WxDxH): 21.6 x 25.6 x 31.8 cm;
- External dimensions (WxDxH): 29.2 x 26.7 x 40 cm.
Similar Products

Horizontal and vertical laminar flow chambers

Laminar flow chambers are designed to restrict an enclosed workspace in the laboratory with forced air circulation inside. The airflow passing through a HEPA filter protects the operator and the working sample from contamination. There are horizontal laminar flow chambers (direction of filtered air horizontally, ensuring protection of the biological materials handled) and vertical laminar flow (direction of filtered air downwards vertically, guaranteeing operator protection against possible risk contaminants). Equipped with long-lasting white light lamps and UV lamps for sterilization.

Class II biological safety chambers

Class II biological safety chambers are ideal laminar flow chambers to protect the operator, the product and the environment. The cabin operates with negative pressure, preventing the release of contaminated air into the environment. Designed to offer total protection, the air circulating inside the chamber is filtered by a HEPA filter (99.999% efficiency), and the fresh air is also filtered through another HEPA filter. They also have an air speed compensation system before the resistance increases by the filter and alarms in case of electrical supply failures. These cameras are used in different areas of research, such as microbiology, virology and genetics and in the various service laboratories, where moderate biological risk samples are handled.